Product Details
Place of Origin: CHINA
Brand Name: TAIMI
Certification: ISO,RoHS CE
Model Number: TM-DHT11 HTMRS03 T/H module Smart Home insert
Payment & Shipping Terms
Minimum Order Quantity: 1000PCS
Price: negotiable
Packaging Details: safe packaging
Delivery Time: 10~20days
Payment Terms: T/T
Supply Ability: 100000/month
Type: |
DHT11 HTMRS03 T/H Module Smart Home Insert |
Full Name: |
HTMRS03 T/H Module Smart Home Insert DHT11 Stabilizes The Digital T/H Sensor |
Relative Humidity Range Ability: |
20~95%RH |
Relative Humidity Accuracy: |
25℃+/-5 %RH |
Power Supply: |
3~5.5 V |
Serial Data (SDA): |
SDA Pins Have A Three-state Structure For Reading And Writing Sensor Data |
Dimensions: |
13*16*5.8 Blue Temperature And Humidity Sensor |
Sampling Period: |
2.0s |
Operating Temperatures: |
- 40 ~+ 135°C |
Wight: |
2g |
Application: |
Humidifier, Dehumidifier, Air Purifier, New Fan, Central Air Conditioning And Other Household Appliances |
Warranty: |
2 Years |
Color: |
White & Blue |
Deliver: |
20days |
Type: |
DHT11 HTMRS03 T/H Module Smart Home Insert |
Full Name: |
HTMRS03 T/H Module Smart Home Insert DHT11 Stabilizes The Digital T/H Sensor |
Relative Humidity Range Ability: |
20~95%RH |
Relative Humidity Accuracy: |
25℃+/-5 %RH |
Power Supply: |
3~5.5 V |
Serial Data (SDA): |
SDA Pins Have A Three-state Structure For Reading And Writing Sensor Data |
Dimensions: |
13*16*5.8 Blue Temperature And Humidity Sensor |
Sampling Period: |
2.0s |
Operating Temperatures: |
- 40 ~+ 135°C |
Wight: |
2g |
Application: |
Humidifier, Dehumidifier, Air Purifier, New Fan, Central Air Conditioning And Other Household Appliances |
Warranty: |
2 Years |
Color: |
White & Blue |
Deliver: |
20days |
Temperature And Humidity Sensor HTMRS03 T/H module Smart Home insert DHT11 Stabilizes the digital T/H sensor
HTMRS03 T/H module Smart Home insert DHT11 Stabilizes the digital T/H sensor
Product overview
This product is a temperature and humidity integrated sensor with calibrated digital signal output. It uses high polymer humidity sensitive resistor as sensing element and is converted into digital signal output after collection and processing by single chip microcomputer. It has the characteristics of long-term stability, high reliability, high precision, low power consumption and so on. Widely used in humidifier, dehumidifier, air purifier, new fan, central air conditioning and other household appliances.
,
Dimensional drawing
Unit: mm (±0.5mm)
Specializing in temperature and humidity sensor field for 20 years.Please connect us get more details:
Email:cherryliu@taimihk.com
Mobile/whatsApp:+86 13538467125
product feature
The new DHT11 digital temperature and humidity module has the following features:
1, digital output, single bus protocol;
2. Low power consumption;
3, 20~95% relative humidity measurement range;
4. Universal 2.54mm connection terminal;
5, temperature drift calibration, good stability.
performance indicators
Table 1 Relative humidity
parameter | condition | Min | typical | Max | unit |
resolution ratio | 1 | %RH | |||
range ability | 20 | 95 | %RH | ||
accuracy | 25℃ | ±5 | ±3 | ±5 | %RH |
repeatability | ±0.1 | ||||
response time | 1/e(63%) | < 8 | S | ||
slow-moving | ±0.5 | %RH | |||
drifting | typical value | < 3 | %RH/y |
Electrical specification
Table 2 Temperature
parameter | condition | Min | typical | Max | unit |
resolution ratio | 0.1 | ℃ | |||
working range | -20 | 60 | ℃ | ||
accuracy | ±0.5 | ℃ | |||
repeatability | ±0.2 | ℃ | |||
response time | 1/e(63%) | 1 | S | ||
slow-moving | ±0.1 | ||||
drifting | typical value | < 0.2 | ℃/y |
Table 3 Io represents low level output current and Rp represents pull-up resistance
parameter | condition | MIN | Typical | Max | Unit |
Power supply voltage VDD | 3.0 | 5 | 5.5 | V | |
|
sleep mode | 0.6 | 2 | uA | |
|
2.0 | 2.5 | mA | ||
sampling period | 2.0 | S | |||
Low output voltage | Io<4mA | 0 | 250 | mV | |
Low output voltage | Rp<25kΩ | 80% | 100% | VDD | |
Low input voltage | falling edge | 0% | 20% | VDD | |
High level input voltage | rising edge | 80% | 100% | VDD | |
current output |
On | 4 | mA | ||
three-state gate(Off) | 10 | 20 | μA |
Single bus interface definition
1,pinout
pin | Name | description |
1 | VDD | power3.0~5.5V |
2 | SDA | Serial data, two-way port |
3 | NC |
|
4 | GND | Land |
Table 1: Pin allocation
2. Single bus communication
1 2 3 4
Figure 1: Pin assignment
2.1,Single bus connection
The microprocessor can be directly connected to the sensor. In single-bus communication mode, the SDA is connected to the I/O port of the processor after being pulled up.
Special instructions for a single bus:
1. In typical application circuit, it is recommended to use 10K pull-up resistance when the connection length is shorter than 30 meters, and then according to the length of the use distance
Short, adjust the size of pull-up resistance.
2. The read interval must be longer than 1S. If the time interval is too short, the temperature and humidity measurement may be inaccurate.
Application information
1. Working conditions
The recommended temperature range is -10 ° C to 60 ° C and the humidity range is 20-95%RH to ensure the normal and stable operation of the sensor. Exceeding the recommended range may cause temporary drift of measurement results.
2. Storage conditions and recovery
The humidity sensor is an environment-sensitive electronic component and requires careful protection. Long-term exposure to high concentrations of chemical vapors will cause the sensor's measurements to drift. Therefore, it is recommended that the sensor be stored in the original package and meet the storage conditions: Temperature range 10 ° C to 50 ° C; Humidity range: 20-60%RH. Sensors should be kept away from high concentrations of chemical solubilizers during production and transportation. Avoid using volatile glues, adhesive tapes, self-adhesive stickers, or volatile packaging materials such as foam bags and styrofoam.
3. Influence of temperature
Relative humidity depends a lot on temperature. The product has been calibrated and compensated for the temperature before leaving the factory. When measuring humidity, the sensor should be ensured to work at the same temperature as far as possible. When installed on the product, it should be kept away from the heat source as far as possible. Otherwise, the relative humidity of the gas cannot be accurately measured.
The sensor adopts passive communication mode, and is in sleep mode when there is no signal received, which is not only to save power but also to better control heat. Therefore, when in use, the wake up frequency should not be too high, otherwise it will be due to automatic heating effect. The recommended sampling period is 2 seconds.